| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
HOYL 600-S-0100600A 5V OL BUS BAR MOUNT |
1,783 |
|
Datasheet | HOYL-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | 1.333mV/A | DC ~ 140kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYL 200-S-0100200A 5V OL BUS BAR MOUNT |
4,427 |
|
Datasheet | HOYL-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 4mV/A | DC ~ 140kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 55-TP/SP27SENSOR CURRENT HALL 50A AC/DC |
3,072 |
|
Datasheet | LA | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.65% | ±12V ~ 15V | 1µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LF 305-SSENSOR CURRENT HALL 300A AC/DC |
4,558 |
|
Datasheet | LF | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | 12V ~ 20V | 1µs | 176mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
LA 125-P/SP4SENSOR CURRENT HALL 125A AC/DC |
4,655 |
|
Datasheet | LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 0.5µs | 10mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
SSA2-250ASMART CURRENT SENSE SHUNT 250 AM |
161 |
|
Datasheet | SSA2 | Module | Bulk | Active | AC/DC | Shunt | 250A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.2% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
|
LF 310-SC/L, ASIC 300A PANEL MOUNT |
118 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | 0.5mA/A | 100kHz | ±0.05% | ±0.2% | 11.4V ~ 21V | 0.5µs | 38mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
SSA2-500ASMART CURRENT SENSE SHUNT 500 AM |
197 |
|
Datasheet | SSA2 | Module | Bulk | Active | AC/DC | Shunt | 500A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.2% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
SSA2-1000ASMART CURRENT SENSE SHUNT 1000 A |
164 |
|
Datasheet | SSA2 | Module | Bulk | Active | AC/DC | Shunt | 1000A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.2% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 205-SSENSOR CURRENT HALL 200A AC/DC |
119 |
|
Datasheet | LA | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | 20mA | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 1500-SSENSOR CURRENT HALL 1500A AC/DC |
2,147 |
|
Datasheet | HAX | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AT 100 B420LSENSOR CURRENT XFMR 100A AC |
193 |
|
Datasheet | AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | 50/60Hz | ±0.5% | ±1.5% | 20V ~ 30V | 100ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 50 B10SENSOR CURRENT 10A, 25A, 50A |
3,936 |
|
Datasheet | APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A, 25A, 50A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 305-SSENSOR CURRENT HALL 300A AC/DC |
4,725 |
|
Datasheet | LA | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | 140mA | 0°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 400 B420LSENSOR CURRENT 200A, 300A, 400A |
2,875 |
|
Datasheet | APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 200A, 300A, 400A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 12V ~ 24V | 400ms | 25mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-SC/L, ASIC 1000A PANEL MOUNT |
3,942 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | 0.2mA/A | 200kHz | ±0.15% | ±0.2% | 14.25V ~ 25.2V | 0.5µs | 49mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
CR5211-10SENSOR CURRENT MAGNETIC 10A DC |
4,380 |
|
Datasheet | CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 10A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
LF 505-SSENSOR CURRENT HALL 500A AC/DC |
112 |
|
Datasheet | LF | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | 124mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR5220-10SENSOR CURRENT MAGNETIC 10A DC |
1,653 |
|
Datasheet | CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 10A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 100mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
SSD-100A-C100A - 24BIT ISOLATED SHUNT CUR |
1,285 |
|
Datasheet | SSD | Module | Bulk | Active | DC | Current Sensor | 100A | 1 | CAN Bus | - | - | ±0.1% | ±0.1% | 5V ~ 60V | - | 55mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.