Current Sense Transformers
Explore Current Sense Transformers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Frequency Range | Type | Current Rating (Amps) | Inductance | ET (Volt-Time) | Turns Ratio - Primary:Secondary | Current Ratio | DC Resistance (DCR) | Ratings | Mounting Type | Size / Dimension | Height - Seated (Max) | Termination Style |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CT1000ACURR SENSE XFMR 5A CHAS MNT |
1,322 |
|
Datasheet | CT | Box | Active | - | Non-Invasive (Solid Core) | 5 A | - | - | - | 1000:5 | - | - | Chassis Mount | 7.000" L x 1.750" W (177.80mm x 44.45mm) | 6.250" (158.75mm) | Wire Leads |
|
CT-1200-F15CURR SENSE XFMR 1200:5 FOOTED |
1,732 |
|
Datasheet | CT | Bulk | Active | - | Non-Invasive (Solid Core) | 1200 A | - | - | - | 1200:5 | - | - | - | - | - | Terminal Block |
|
PA0368.100NLCURR SENSE XFMR 1:100 4A SMD |
3,577 |
|
Datasheet | - | Tube | Active | 50kHz ~ 1MHz | Invasive | 4 A | 6.7 mH | - | 1:100 | - | 4mOhm Primary, 1.6Ohm Secondary | - | Surface Mount | 0.285" L x 0.352" W (7.25mm x 8.25mm) | 0.124" (3.15mm) | - |
|
56T200CCURR SENSE XFMR 10A T/H |
2,360 |
|
Datasheet | 5600 | Box | Active | 20kHz ~ 200kHz | Non-Invasive (Solid Core) | 10 A | - | - | - | 200CT:1 | 1.87mOhm Primary, 2.81mOhm Secondary | - | Through Hole | 0.661" L x 0.350" W (16.79mm x 8.89mm) | 0.795" (20.19mm) | PC Pin |
|
PMS9494.200NLTXFMR SENSE SMT EE8.5 30A 200:1 |
2,682 |
|
Datasheet | - | Tape & Reel (TR) | Active | 20kHz ~ 1MHz | Invasive | 30 A | 9 mH | - | 1.50:200 | 200:1.50 | 0.35mOhm Primary, 14Ohm Secondary | - | Surface Mount | 0.512" L x 0.413" W (13.00mm x 10.50mm) | 0.283" (7.20mm) | Gull Wing |
|
PMS9494.100NLTXFMR SENSE SMT EE8.5 30A 100:1 |
1,678 |
|
Datasheet | - | Tape & Reel (TR) | Active | 20kHz ~ 1MHz | Invasive | 30 A | 2.2 mH | - | 1.50:100 | 100:1.50 | 0.35mOhm Primary, 3.3Ohm Secondary | - | Surface Mount | 0.512" L x 0.413" W (13.00mm x 10.50mm) | 0.283" (7.20mm) | Gull Wing |
|
PMS9494.050NLTXFMR SENSE SMT EE8.5 30A 50:1 |
3,348 |
|
Datasheet | - | Tape & Reel (TR) | Active | 20kHz ~ 1MHz | Invasive | 30 A | 550 µH | - | 1.50:50 | 50:1.50 | 0.35mOhm Primary, 660mOhm Secondary | - | Surface Mount | 0.512" L x 0.413" W (13.00mm x 10.50mm) | 0.283" (7.20mm) | Gull Wing |
|
7492550500CURRENT SENSE TRANSFORMER 187EI |
4,547 |
|
Datasheet | WE-CSTLF | Tray | Active | 400Hz | Invasive | 45 A | - | - | 1:500 | 500:1 | 0.27mOhm Primary, 16.2Ohm Secondary | - | Through Hole | - | 0.795" (20.20mm) | PC Pin |
|
2525160000CMA-CTM-7-SNAP-ON |
2,703 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CT-1075CURR SENSE XFMR 75A T/H |
2,475 |
|
Datasheet | CT | Bulk | Active | 50/60Hz | Non-Invasive (Solid Core) | 75 A | - | - | - | 1000:1 | 24Ohm | - | Through Hole | 1.500" L x 0.626" W (38.10mm x 15.90mm) | 1.500" (38.10mm) | PC Pin |
|
TWCT-T-D55 200/5A VA 5 CL 1TAPE WOUND CT WITH 200/5A |
1,896 |
|
Datasheet | TWCT | Box | Active | 50Hz ~ 60Hz | Non-Invasive (Solid Core) | - | - | - | - | 200:5 | - | - | Free Hanging (In-Line) | 3.937" L x 3.543" W (100.00mm x 90.00mm) | 0.984" (25.00mm) | Wire Leads |
|
TWCT-T-D55 150/5A VA 5 CL 1TAPE WOUND CT WITH 150/5A |
1,713 |
|
Datasheet | TWCT | Box | Active | 50Hz ~ 60Hz | Non-Invasive (Solid Core) | - | - | - | - | 150:5 | - | - | Free Hanging (In-Line) | 3.937" L x 3.543" W (100.00mm x 90.00mm) | 0.984" (25.00mm) | Wire Leads |
|
TWCT-T-D110 1000/5A VA 10 CL 0.5TAPE WOUND CT WITH 1000/5A |
3,263 |
|
Datasheet | TWCT | Box | Active | 50Hz ~ 60Hz | Non-Invasive (Solid Core) | - | - | - | - | 1000:5 | - | - | Free Hanging (In-Line) | 5.709" L x 1.378" W (145.00mm x 35.00mm) | 1.378" (35.00mm) | Wire Leads |
|
CRZ8465-2K5WZERO SEQUENCE CURRENTTRANSFORMER |
3,227 |
|
Datasheet | CRZ | Box | Active | 50Hz ~ 60Hz | Non-Invasive (Solid Core) | - | - | - | 1:2000:5 | - | 170Ohm | - | Free Hanging (In-Line) | 2.165" L x 2.047" W (55.00mm x 52.00mm) | 0.472" (12.00mm) | Wire Leads |
|
2526810000WIL-MAGNET |
3,893 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
2277682PACT MCR-V2-4012- 70- 500-5A-1 |
1,201 |
|
Datasheet | - | Bulk | Active | 50Hz ~ 60Hz | Non-Invasive (Solid Core) | 500 A | - | - | - | - | - | - | DIN Rail | 2.756" L x 1.181" W (70.00mm x 30.00mm) | 3.543" (90.00mm) | Terminal Block |
|
2420950000CMA-31-200-5A-5VA-1 |
4,675 |
|
Datasheet | - | Box | Active | 50Hz | Non-Invasive (Solid Core) | 200 A | - | - | - | - | - | - | DIN Rail | 2.362" L x 2.047" W (60.00mm x 52.00mm) | 3.185" (80.90mm) | Terminal Block |
|
2421380000CMA-31-60-5A-1,25VA-1 |
2,695 |
|
Datasheet | - | Box | Active | 50Hz | Non-Invasive (Solid Core) | 60 A | - | - | - | - | - | - | DIN Rail | 2.362" L x 2.047" W (60.00mm x 52.00mm) | 3.185" (80.90mm) | Terminal Block |
|
SCCT 80/50 800/5A VA 3 CL 0.5 -CESPLIT CORE CURRENT TRANSFORMER 8 |
2,452 |
|
Datasheet | SCCT | Box | Active | 50Hz ~ 60Hz | Non-Invasive (Split Core) | - | - | - | - | 800:5 | - | - | Chassis Mount | - | 6.319" (160.50mm) | Terminal Block |
|
SCCT 30/20 100/5 A VA 1 CL 1 -CESPLIT CORE CURRENT TRANSFORMER. |
3,177 |
|
Datasheet | SCCT | Box | Active | 50Hz ~ 60Hz | Non-Invasive (Split Core) | - | - | - | - | 100:5 | - | - | Chassis Mount | - | 4.311" (109.50mm) | Terminal Block |
Frequently Asked Questions
What are Current Sense Transformers components used for?
Current Sense Transformers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sense Transformers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sense Transformers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.