Contactors (Electromechanical)
Explore Contactors (Electromechanical) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Features | Termination Style | Operating Temperature | Must Operate Voltage | Must Release Voltage |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3TG10010BB4CONTACTOR,3NO+1NC,OPER.,24VDC |
3,655 |
|
Datasheet | - | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 20 A | 400VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 55°C | - | - |
|
3TG10100BB4CONTACTOR SCREW TERMINALS_4NO_24 |
4,487 |
|
Datasheet | - | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 8.4 A | 400VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 55°C | - | - |
|
3RT20361AK643MA0CONTACTOR S2 50A 120VAC SCREW 2N |
4,244 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 120VAC | 3PST-NO (3 Form A) | 51 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 96 VAC | - |
|
2-2071410-1IHV200HAANA |
3,079 |
|
Datasheet | IHV200 | Bulk | Active | Chassis Mount | 12 ~ 24VDC | SPST-NO (DM) (1 Form X) | 200 A | 900VDC - Max | - | Stud, Wire Leads | -40°C ~ 85°C | 32 VDC | 18 VDC |
|
GX16CEGX SERIES POWER CONTACTOR |
3,823 |
|
Datasheet | GX16 | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 600 A | 800VDC - Max | Sealed - Hermetically | Connector, Stud | -55°C ~ 85°C | 16 VDC | 0.5 VDC |
|
HX22CABHX SERIES POWER CONTACTOR |
2,404 |
|
Datasheet | HX22 | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 300 A | 1500VDC - Nom | Auxiliary Contacts, Sealed - Hermetically | Stud, Wire Leads | -55°C ~ 85°C | 16 VDC | 0.5 VDC |
|
LC1D50AG7TESYS 3P EVLK CTR 50A 22KW AC3 1 |
2,530 |
|
Datasheet | TeSys | Box | Active | Chassis Mount | 120VAC | 3PST-NO (3 Form A) | 25 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 60°C | 102 VAC | 36 VAC |
|
LC1D50AF7TESYS 3P EVLK CTR 50A 22KW AC3 1 |
2,202 |
|
Datasheet | TeSys | Box | Active | Chassis Mount, DIN Rail | 110VAC | 3PST-NO (3 Form A) | 50 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 93.5 VAC | 33 VAC |
|
GX16BEBGX SERIES POWER CONTACTOR |
1,640 |
|
Datasheet | GX16 | Bulk | Active | Chassis Mount | 12VDC | SPST-NO (DM) (1 Form X) | 600 A | 800VDC - Max | Auxiliary Contacts, Sealed - Hermetically | Connector, Stud | -55°C ~ 85°C | 8 VDC | 0.5 VDC |
|
HX22CBBHX SERIES POWER CONTACTOR |
2,448 |
|
Datasheet | HX22 | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 300 A | 1500VDC - Nom | Auxiliary Contacts, Sealed - Hermetically | Stud, Wire Leads | -55°C ~ 85°C | 16 VDC | 0.5 VDC |
|
GX66CDBGX SERIES POWER CONTACTOR |
4,386 |
|
Datasheet | GX66 | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 600 A | 800VDC - Max | Auxiliary Contacts, Sealed - Hermetically | Screw Terminal | -55°C ~ 85°C | 16 VDC | 0.5 VDC |
|
3RT20262XB400LA2CONTACTOR RAIL S0 25A 24VDC 1NO/ |
1,277 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 25 A | 690VAC - Max | Auxiliary Contacts | Spring Terminal | -40°C ~ 70°C | 16.8 VDC | - |
|
DCNEVT350-BADC CONTACTOR 350A 1800V 12VIN |
3,211 |
|
Datasheet | DCNEVT350 | Bulk | Active | Chassis Mount | 12VDC | SPST-NO (DM) (1 Form X) | 350 A | 1.8kVDC - Nom | Auxiliary Contacts | Stud, Wire Leads | -40°C ~ 85°C | 10 VDC | 4 VDC |
|
LC1D80G7CONTACTOR |
4,778 |
|
Datasheet | TeSys | Box | Active | Chassis Mount, DIN Rail | 120VAC | 3PST-NO (3 Form A) | 80 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 102 VAC | 36 VAC |
|
LC1D80F73P CONT 80A AC3 37KW 1NO 1NC 110 |
4,694 |
|
Datasheet | TeSys | Box | Active | Chassis Mount, DIN Rail | 110VAC | 3PST-NO (3 Form A) | 80 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 93.5 VAC | 33 VAC |
|
LC2D09JLTESYS REVERSING CONTACTOR |
2,780 |
|
Datasheet | TeSys | Box | Active | Chassis Mount, DIN Rail | 12VDC | 3PST-NO (3 Form A) | 9 A | 690VAC, 300VDC - Max | Auxiliary Contacts, Diode | Screw Terminal | -40°C ~ 70°C | 9.6 VDC | 1.2 VDC |
|
LC2D12F7TESYS3PREVERS CTR12AAC3 5.5KW110 |
1,071 |
|
Datasheet | TeSys | Box | Active | Chassis Mount, DIN Rail | 110VAC | 3PST-NO (3 Form A) | 12 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 93.5 VAC | 33 VAC |
|
LC1D65AG7TESYS 3P EVLK CTR 65A 30KW AC3 1 |
1,993 |
|
Datasheet | TeSys | Box | Active | Chassis Mount, DIN Rail | 120VAC | 3PST-NO (3 Form A) | 65 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 102 VAC | 36 VAC |
|
LC1D65AB7TESYS 3P EVLK CTR 65A 30KW AC3 2 |
4,015 |
|
Datasheet | TeSys | Box | Active | Chassis Mount, DIN Rail | 24VAC | 3PST-NO (3 Form A) | 65 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 20.4 VAC | 7.2 VAC |
|
3RT20373KB40CONTACTOR S2 65A 24VDC SPRING 1N |
3,863 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 65 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 19.2 VDC | - |
Frequently Asked Questions
What are Contactors (Electromechanical) components used for?
Contactors (Electromechanical) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Contactors (Electromechanical) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Contactors (Electromechanical) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.