| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Features | Termination Style | Operating Temperature | Must Operate Voltage | Must Release Voltage |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LCE04C303240ACONTACTOR,LTG,EH,N4X,30A,3NC,3NO |
1,428 |
|
Datasheet | Class LC | Bulk | Active | Chassis Mount | 230 ~ 240VAC | 6PST-3NO/3NC (3 Form A, 3 Form B) | 30 A | 600VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 40°C | - | - |
|
LCE04C600208ACONTACTOR,LTG,EH,N4X,30A,6NC,0NO |
3,653 |
|
Datasheet | Class LC | Bulk | Active | Chassis Mount | 200 ~ 208VAC | 6PST-NC (6 Form B) | 30 A | 600VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 40°C | - | - |
|
G71B87170KV SPST-NC HV RELAY |
4,982 |
|
Datasheet | G71B | Box | Active | Panel Mount | 26.5VDC | SPST-NC (1 Form B) | 10 A | 30000VAC, 70000VDC - Max | - | Solder Turret, Wire Leads | -50°C ~ 85°C | 22 VDC | 1 VDC |
|
8903LG80V02CLIGHTING CONTACTOR 600VAC 30A L |
4,952 |
|
Datasheet | Square D | Box | Active | Chassis Mount | 120VAC | 8PST-NO (8 Form A) | 30 A | 600VAC - Max | - | Screw Terminal | - | - | - |
|
3RT20461KB401AA0COUPL. CONT.. AC3:45KW. 1NO+1NC. |
4,813 |
|
Datasheet | 3RT2 | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 95 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 19.2 VDC | - |
|
T02DN23G7REV. CONTACTOR TESYS NEMA SZ 2, |
4,211 |
|
Datasheet | TeSys | Box | Active | Chassis Mount | 120VAC | 3PST-NO (3 Form A) | 45 A | 600VAC - Max | Auxiliary Contacts | Screw Terminal | - | - | - |
|
3RT10556PP35CONTACTOR S6 150A 200-277VUC 3P |
1,615 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 200 ~ 277VAC/DC | 3PST-NO (3 Form A) | 150 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
|
3RT10556PF35CONTACTOR S6 150A 96-127VUC 3P R |
2,441 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 96 ~ 127VAC/DC | 3PST-NO (3 Form A) | 150 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
|
LC1G330KUENCONTACTORTESYSGIGA330 3PSTD100-2 |
2,364 |
|
Datasheet | TeSys Giga | Box | Active | Chassis Mount | 100 ~ 250VAC/DC | 3PST-NO (3 Form A) | 330 A | 1000VAC, 460VDC - Max | Auxiliary Contacts | Box Lug | -40°C ~ 70°C | - | - |
|
FM200DAYFM200DAY=RELAY, SPST-NC, 24VDC C |
3,496 |
|
Datasheet | FM200 | Bulk | Active | Chassis Mount | 24VDC | SPST-NO (DM) (1 Form X) | 200 A | 750VAC, 60VDC - Max | Auxiliary Contacts | Quick Connect - 0.250" (6.3mm) | -20°C ~ 60°C | 19.2 VDC | 4.8 VDC |
|
CC265/4SA500RLY CONT 4P 500V 50/60HZ 2NO/2NC |
1,391 |
|
Datasheet | CC | Bulk | Active | Chassis Mount, DIN Rail | 500VAC | 4PST-NO (4 Form A) | 265 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -5°C ~ 60°C | 425 VAC | 150 VAC |
|
CC265/4SAD200RLY CONT 4P 200VACDC 2NO/2NC |
3,464 |
|
Datasheet | CC | Bulk | Active | Chassis Mount, DIN Rail | 200VAC/DC | 4PST-NO (4 Form A) | 265 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -5°C ~ 60°C | - | - |
|
G71LA841LATCHING HV RELAY, 70KV |
4,150 |
|
Datasheet | G71LA | Box | Active | Panel Mount | 26.5VDC | SPST-NO (1 Form A) | 10 A | 30000VAC, 70000VDC - Max | - | Solder Turret, Wire Leads | -55°C ~ 85°C | 22 VDC | 1 VDC |
|
8903LXO0012V02LIGHTING CONTACTOR 600VAC 30A LX |
1,356 |
|
Datasheet | Square D | Box | Active | Chassis Mount, DIN Rail | 120VAC | 12PST-NC (12 Form B) | 30 A | 600VAC - Max | - | Screw Terminal | - | - | - |
|
LC1G2254EHENCONTACTORTESYSGIGA225 4P STD48-1 |
1,333 |
|
Datasheet | TeSys Giga | Box | Active | Chassis Mount | 48 ~ 130VAC/DC | 4PST-NO (4 Form A) | 330 A | 1000VAC, 460VDC - Max | Auxiliary Contacts | Spring Terminal | -40°C ~ 70°C | - | - |
|
LC1G2254KUENCONTACTORTESYSGIGA225 4PSTD100-2 |
1,595 |
|
Datasheet | TeSys Giga | Box | Active | Chassis Mount | 100 ~ 250VAC/DC | 4PST-NO (4 Form A) | 330 A | 1000VAC, 460VDC - Max | Auxiliary Contacts | Spring Terminal | -40°C ~ 70°C | - | - |
|
3RT10561AB36CONTACTOR AC3,90KW/400V 2NO+2NC |
2,979 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 23 ~ 26VAC/DC | 3PST-NO (3 Form A) | 185 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
|
3RT10646AF363PA0CONTACTOR S10 225A 110-127VUC 3P |
1,110 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 110 ~ 127VAC/DC | 3PST-NO (3 Form A) | 225 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
|
3RT10646AB363PA0CONTACTOR S10 225A 23-26VUC 2NO/ |
3,611 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 23 ~ 26VAC/DC | 3PST-NO (3 Form A) | 225 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
|
3RT14566PF35CONTACTOR. 275A/AC-1 |
1,729 |
|
Datasheet | SIRIUS | Box | Active | Chassis Mount, DIN Rail | 96 ~ 127VAC/DC | 3PST-NO (3 Form A) | 275 A | 1000VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | - | - |
Frequently Asked Questions
What are Contactors (Electromechanical) components used for?
Contactors (Electromechanical) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Contactors (Electromechanical) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Contactors (Electromechanical) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.