JIEXIN Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Contactors (Electromechanical)

Explore Contactors (Electromechanical) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
3RE41615BA300YY0 Siemens

3RE41615BA300YY0

CONTACTOR,FVNR,SZ S00,3PH,120VAC

Siemens

2,750
Datasheet - Box Active Chassis Mount 120VAC 3PST-NO (3 Form A) - 600VAC - Max Auxiliary Contacts Screw Terminal -20°C ~ 40°C 96 VAC -
3RH24311LW800LA0 Siemens

3RH24311LW800LA0

LATCHED CONT RELAY FOR RAILWAY A

Siemens

2,910
Datasheet SIRIUS Box Active Chassis Mount, DIN Rail 32VDC 3PST-NO (3 Form A) 10 A 690VAC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 22.4 VDC -
2-1618396-6 TE Connectivity Aerospace, Defense and Marine

2-1618396-6

EV200AXANA02=RELAY, EV200 BATTER

TE Connectivity Aerospace, Defense and Marine

1,298
Datasheet - Bulk Active - - - - - - - - - -
3RE41623BA300YY0 Siemens

3RE41623BA300YY0

CONTACTOR,FVNR,SIZE S0,3PH,120VA

Siemens

4,762
Datasheet - Box Active Chassis Mount 120VAC 3PST-NO (3 Form A) - 600VAC - Max Auxiliary Contacts Screw Terminal -20°C ~ 40°C 96 VAC -
LC2D18BD Schneider Electric

LC2D18BD

TESYS REVERSING CONTACTOR

Schneider Electric

2,915
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VDC 3PST-NO (3 Form A) 18 A 690VAC, 300VDC - Max Auxiliary Contacts, Diode Screw Terminal -40°C ~ 70°C 16.8 VDC 2.4 VDC
3RT20282NP30 Siemens

3RT20282NP30

CONTACTOR S0 38A 200-280VUC 1NO/

Siemens

3,291
Datasheet SIRIUS Box Active Chassis Mount, DIN Rail 200 ~ 280VAC/DC 3PST-NO (3 Form A) 38 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 60°C - -
3RT20282NB30 Siemens

3RT20282NB30

CONTACTOR S0 38A 21-28VUC 1NO/1N

Siemens

2,711
Datasheet SIRIUS Box Active Chassis Mount, DIN Rail 21 ~ 28VAC/DC 3PST-NO (3 Form A) 38 A 690VAC - Max Auxiliary Contacts Spring Terminal -25°C ~ 60°C - -
3RT20281NB30 Siemens

3RT20281NB30

CONTACTOR S0 38A 21-28VUC 1NO/1N

Siemens

2,683
Datasheet SIRIUS Box Active Chassis Mount, DIN Rail 21 ~ 28VAC/DC 3PST-NO (3 Form A) 38 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 60°C - -
3RT20281NP30 Siemens

3RT20281NP30

CONTACTOR S0 38A 200-280VUC 1NO/

Siemens

4,282
Datasheet SIRIUS Box Active Chassis Mount, DIN Rail 200 ~ 280VAC/DC 3PST-NO (3 Form A) 38 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 60°C - -
3RT20282NF30 Siemens

3RT20282NF30

CONTACTOR S0 38A 95-130VUC 1NO/1

Siemens

4,362
Datasheet SIRIUS Box Active Chassis Mount, DIN Rail 95 ~ 130VAC/DC 3PST-NO (3 Form A) 38 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 60°C - -
3RT20281NF30 Siemens

3RT20281NF30

CONTACTOR S0 38A 95-130VUC 1NO/1

Siemens

3,963
Datasheet SIRIUS Box Active Chassis Mount, DIN Rail 95 ~ 130VAC/DC 3PST-NO (3 Form A) 38 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 60°C - -
LC1D80AQ7 Schneider Electric

LC1D80AQ7

TESYS 3P EVLK CTR 80A 37KW AC3 3

Schneider Electric

1,729
Datasheet TeSys Box Active Chassis Mount, DIN Rail 380VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 323 VAC 114 VAC
LC1D80A3E7 Schneider Electric

LC1D80A3E7

TESYS 3P EVLK CTR 80A 37KW AC3 4

Schneider Electric

3,758
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Spring Terminal -40°C ~ 70°C 38.4 VAC 14.4 VAC
LC1D80AV7 Schneider Electric

LC1D80AV7

TESYS 3P EVLK CTR 80A 37KW AC3 4

Schneider Electric

4,601
Datasheet TeSys Box Active Chassis Mount, DIN Rail 400VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 320 VAC 120 VAC
LC1D80A3F7 Schneider Electric

LC1D80A3F7

TESYS 3P EVLK CTR 80A 37KW AC3 1

Schneider Electric

2,735
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Spring Terminal -40°C ~ 70°C 88 VAC 33 VAC
LC1D80AE7 Schneider Electric

LC1D80AE7

TESYS 3P EVLK CTR 80A 37KW AC3 4

Schneider Electric

2,870
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 38.4 VAC 14.4 VAC
LC1D80AU7 Schneider Electric

LC1D80AU7

TESYS 3P EVLK CTR 80A 37KW AC3 2

Schneider Electric

1,148
Datasheet TeSys Box Active Chassis Mount, DIN Rail 240VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 192 VAC 72 VAC
LC1D80A3P7 Schneider Electric

LC1D80A3P7

TESYS 3P EVLK CTR 80A 37KW AC3 2

Schneider Electric

4,131
Datasheet TeSys Box Active Chassis Mount, DIN Rail 230VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Spring Terminal -40°C ~ 70°C 184 VAC 69 VAC
LC1D80AR7 Schneider Electric

LC1D80AR7

TESYS 3P EVLK CTR 80A 37KW AC3 4

Schneider Electric

4,208
Datasheet TeSys Box Active Chassis Mount, DIN Rail 440VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 374 VAC 132 VAC
LC1D80AN7 Schneider Electric

LC1D80AN7

TESYS 3P EVLK CTR 80A 37KW AC3 4

Schneider Electric

3,651
Datasheet TeSys Box Active Chassis Mount, DIN Rail 415VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 332 VAC 124.5 VAC
Total 14795 Record«Prev1... 368369370371372373374375...740Next»
FAQ

Frequently Asked Questions

What are Contactors (Electromechanical) components used for?

Contactors (Electromechanical) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Contactors (Electromechanical) part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Contactors (Electromechanical) parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Contactors (Electromechanical)?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top