Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
153200HIGH AMP CB-TYPE III MANUAL,200A |
1,538 |
|
Datasheet | 153 | Bulk | Active | - | - | 200A | - | 42 V | Push to Reset | 1 | None | - | ABYC-E11, IEC 60934, IP 67, SAE J1171, SAE J1625 |
|
153180HIGH AMP CB-TYPE III MANUAL,180A |
345 |
|
Datasheet | 153 | Bulk | Active | - | - | 180A | - | 42 V | Push to Reset | 1 | None | - | ABYC-E11, IEC 60934, IP 67, SAE J1171, SAE J1625 |
|
APL1-1REC4-52-502CIRCUIT BRKR MAG-HYDR LEVER 5A |
3,291 |
|
Datasheet | APL | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 277 V | 65 V | Lever | 1 | - | - | - |
|
IUGBX1-32101-14CIR BRKR MAG-HYDR ROCKER |
6,160 |
|
Datasheet | IUG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Rocker | 1 | - | - | - |
|
EA2-B0-16-912-22A-BCCIR BRKR 125A 600VAC 125VDC |
7,620 |
|
Datasheet | E | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 125A | - | 125 V | Lever | 2 | None | - | CCC, CSA, UL489, VDE |
|
IALR1-23356-1CIRCUIT BREAKER MAG-HYDR LEVER |
7,419 |
|
Datasheet | IELR | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
P1MB3PC203 POLE, CURVE C, 20A, 230/400VAC |
2,395 |
|
Datasheet | P1MB3P | Box | Active | DIN Rail | Thermal Magnetic | 20A | 400 V | - | Lever | 3 | None | - | CSA C22.2 No. 235, cURus, EAC, IEC 60898-1, IEC 60947-2, TUV-Rheinland, UL 1077 |
|
P1MB3PC133 POLE, CURVE C, 13A, 230/400VAC |
2,342 |
|
Datasheet | P1MB3P | Box | Active | DIN Rail | Thermal Magnetic | 13A | 400 V | - | Lever | 3 | None | - | CSA C22.2 No. 235, cURus, EAC, IEC 60898-1, IEC 60947-2, TUV-Rheinland, UL 1077 |
|
P1MB3PC253 POLE, CURVE C, 25A, 230/400VAC |
3,524 |
|
Datasheet | P1MB3P | Box | Active | DIN Rail | Thermal Magnetic | 25A | 400 V | - | Lever | 3 | None | - | CSA C22.2 No. 235, cURus, EAC, IEC 60898-1, IEC 60947-2, TUV-Rheinland, UL 1077 |
|
P1MB3PC033 POLE, CURVE C, 3A, 230/400VAC |
1,597 |
|
Datasheet | P1MB3P | Box | Active | DIN Rail | Thermal Magnetic | 3A | 400 V | - | Lever | 3 | None | - | CSA C22.2 No. 235, cURus, EAC, IEC 60898-1, IEC 60947-2, TUV-Rheinland, UL 1077 |
|
IELK1-1-61-30.0-01-VCIR BRKR MAG-HYDR LEVER 30A |
8,614 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 30A | - | - | Lever | 1 | - | - | - |
|
351120HIGH AMP CB-TYPE I AUTO, 120A |
992 |
|
Datasheet | 351 | Bulk | Active | - | - | 120A | - | 48 V | Automatic Reset | 1 | None | - | ABYC-E11, IP 67, SAE J1171, SAE J1625, UL 1077 |
|
351080HIGH AMP CB-TYPE I AUTO, 80A |
905 |
|
Datasheet | 351 | Bulk | Active | - | - | 80A | - | 48 V | Automatic Reset | 1 | None | - | ABYC-E11, IP 67, SAE J1171, SAE J1625, UL 1077 |
|
351060HIGH AMP CB-TYPE I AUTO, 60A |
440 |
|
Datasheet | 351 | Bulk | Active | - | - | 60A | - | 48 V | Automatic Reset | 1 | None | - | ABYC-E11, IP 67, SAE J1171, SAE J1625, UL 1077 |
|
351150HIGH AMP CB-TYPE I AUTO, 150A |
314 |
|
Datasheet | 351 | Bulk | Active | - | - | 150A | - | 48 V | Automatic Reset | 1 | None | - | ABYC-E11, IP 67, SAE J1171, SAE J1625, UL 1077 |
|
151200HIGH AMPS CB - TYPE I AUTO, 200A |
3,495 |
|
Datasheet | 151 | Bulk | Active | - | - | 200A | - | 42 V | Automatic Reset | 1 | None | - | ABYC-E11, IP 67, SAE J1171, SAE J1625 |
|
W91-X150-5CIR BRKR MAG-HYDR 5A 65VDC |
2,815 |
|
Datasheet | W9 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | - | 65 V | Toggle | 1 | - | - | - |
|
IEL1-1-63F-20.0-01-VCIR BRKR MAG-HYDR LEVER 20A |
2,235 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | - | - | Lever | 1 | - | - | - |
|
IEL1-1-63F-15.0-01-VCIR BRKR MAG-HYDR LEVER 15A |
8,727 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | - | - | Lever | 1 | - | - | - |
|
IDLK1-224-58CIRCUIT BREAKER MAG-HYDR LEVER |
2,933 |
|
Datasheet | IDL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.