| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HDL26060MOLDED CASE CIRCUIT BREAKER 600V |
4,779 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 60A | 690 V | 250 V | Toggle | 2 | None | - | CSA, UL |
|
HDL26015MOLDED CASE CIRCUIT BREAKER 600V |
9,161 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 15A | 690 V | 250 V | Toggle | 2 | None | - | CSA, UL |
|
BDL26040MOLDED CASE CIRCUIT BRKR 600Y/34 |
4,001 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 40A | 600 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
HDL26050MOLDED CASE CIRCUIT BREAKER 600V |
9,870 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 50A | 600 V | 250 V | Toggle | 2 | None | - | CSA, UL |
|
BDL26080MOLDED CASE CIRCUIT BRKR 600Y/34 |
4,670 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 80A | 600 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDL26070MOLDED CASE CIRCUIT BRKR 600Y/34 |
2,348 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 70A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
HDL26020MOLDED CASE CIRCUIT BREAKER 600V |
4,729 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 20A | 600 V | 250 V | Toggle | 2 | None | - | CSA, UL |
|
HDL26080MOLDED CASE CIRCUIT BREAKER 600V |
3,603 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 80A | 690 V | - | Toggle | 2 | None | - | CSA, UL, IEC 60947-2 |
|
HDL26070MOLDED CASE CIRCUIT BREAKER 600V |
2,830 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 70A | 600 V | 250 V | Toggle | 2 | None | - | CSA, UL |
|
BGL36000S12AUTOMATIC MOLDED CASE SWITCH 600 |
2,338 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Magnetic | 125A | 600 V | - | Toggle | 3 | None | - | UL |
|
HDL36025MOLDED CASE CIRCUIT BREAKER 600V |
2,204 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 25A | 600 V | 250 V | Toggle | 3 | None | - | CSA, UL |
|
BGL26020MOLDED CASE CIRCUIT BRKR 600Y/34 |
3,003 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 20A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BGL26015MOLDED CASE CIRCUIT BRKR 600Y/34 |
3,406 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 15A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDL36090MOLDED CASE CIRCUIT BRKR 600Y/34 |
3,022 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 90A | 600 V | - | Toggle | 3 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
HDL36035MOLDED CASE CIRCUIT BREAKER 600V |
3,892 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 35A | 690 V | 250 V | Toggle | 3 | None | - | CSA, UL |
|
HDL36060U31XMOLDED CASE CIRCUIT BREAKER 600V |
1,394 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Solid State | 60A | 690 V | - | Toggle | 3 | Green, Orange, Red | - | CSA, UL |
|
HGL26015MOLDED CASE CIRCUIT BREAKER 600V |
2,296 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 15A | 690 V | 500 V | Toggle | 2 | None | - | CSA, UL |
|
HGL26030MOLDED CASE CIRCUIT BREAKER 600V |
2,296 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 30A | 690 V | - | Toggle | 2 | None | - | CSA, UL |
|
HGL26040MOLDED CASE CIRCUIT BREAKER 600V |
3,592 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 40A | 690 V | 500 V | Toggle | 2 | None | - | CSA, UL |
|
HDL36080MOLDED CASE CIRCUIT BREAKER 600V |
2,074 |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 80A | 600 V | 250 V | Toggle | 3 | None | - | CSA, IEC 60947-2, UL |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.