Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
GSB633PC6MCB UL1077 C 3P 6A |
2,229 |
|
Datasheet | GSB63 | Box | Active | DIN Rail | Thermal Magnetic | 6A | 480 V | - | Lever | 3 | None | - | UL1077 |
|
T21-2-3.00A-02-20BLSCIR BRKR MAG-HYDR 3A TOGGLE |
4,793 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 3A | - | - | Toggle | 2 | - | - | - |
|
4230-T130-K0DE-40ACIR BRKR THERM 40A 480VAC/125VDC |
3,981 |
|
Datasheet | 4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 40A | 480 V | 125 V | Lever | 3 | None | - | CSA C22.2 No 235, UL1077 |
|
4230-T130-K0CE-20ACIR BRKR THERM 20A 480VAC/125VDC |
4,276 |
|
Datasheet | 4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 20A | 480 V | 125 V | Lever | 3 | None | - | CSA C22.2 No 235, UL1077 |
|
4430.0707CIR BRKR THRM 6A 240VAC 60VDC |
6,767 |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | 6A | 240 V | 60 V | Rocker | 2 | - | - | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
|
IEG6-1-63-4.00-01-VCIR BRKR MAG-HYDR 4A LEVER |
2,005 |
|
Datasheet | IEG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 4A | 250 V | - | Lever | 1 | None | - | CSA, TUV, UL1077 |
|
IEG6-1-51-20.0-01-VCIR BRKR MAG-HYDR LEVER 20A |
8,582 |
|
Datasheet | IEG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | - | 80 V | Lever | 1 | None | - | CSA, TUV, UL1077 |
|
IEG6-34838-50-VCIR BRKR MAG-HYDR LEVER |
2,902 |
|
Datasheet | IEG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | CSA, TUV, UL1077 |
|
PR21-4-20.0A-XX-VCIR BRKR MAG-HYDR 20A PUSH-RESET |
2,593 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 125 V | 32 V | Push to Reset | 2 | - | - | UL1077 |
|
PR21-62F-3.00A-XX-VCIR BRKR MAG-HYDR 3A PUSH-RESET |
3,447 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 3A | - | - | Push to Reset | 2 | - | - | - |
|
R21-62F-10.0A-R06CV-VCIRCUIT BREAKER 10A ROCKER |
4,196 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | 250 V | 65 V | Rocker | 2 | None | - | - |
|
2-6500-P10-5ACIR BRKR THRM 5A |
4,453 |
|
Datasheet | 2-6500 | Bulk | Active | Panel Mount | Thermal | 5A | 250 V | 28 V | Automatic Reset | 1 | None | - | CSA C22.2 No 235, UL1077 |
|
C5A2P-125VDCCIRCUIT BREAKER 5A 125VDC |
1,244 |
|
Datasheet | - | Box | Active | DIN Rail | Magnetic (Hydraulic Delay) | 5A | - | 125 V | Lever | 2 | - | - | CE, UL489, UR |
|
1C4ULCIR BRKR THRM-MAG 4A LEVER |
2,927 |
|
Datasheet | UL | Bulk | Active | DIN Rail | Thermal Magnetic | 4A | 277 V | - | Lever | 1 | None | - | CE, cULus, UL489 |
|
T20-S-SW-26378-1CIRCUIT BREAKER MAG-HYDR TOGGLE |
4,607 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Toggle | 2 | - | - | - |
|
2481020000CB PROTECTOR 1077 2P D 4A ACDC |
3,722 |
|
Datasheet | MCB 1077 | Bulk | Active | DIN Rail | Thermal Magnetic | 4A | 480 V | 125 V | Lever | 2 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
|
3120-N521-P7T1-W02D-10ACIR BRKR THERM SWITCH 2P |
4,274 |
|
Datasheet | 3120-N | Bulk | Active | Panel Mount | Thermal | 10A | 415 V | 50 V | Rocker | 2 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
2480420000CB PROTECTOR 1077 2P C 32A ACDC |
3,591 |
|
Datasheet | MCB 1077 | Bulk | Active | DIN Rail | Thermal Magnetic | 32A | 480 V | 125 V | Lever | 2 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
|
REX12-TA1-107-DC24V-1ACIR BRKR 1A 24VDC PUSH TO RESET |
1,351 |
|
Datasheet | REX12 | Box | Active | Holder | Solid State | 1A | - | 30 V | Push to Reset | 1 | Green, Orange, Red | - | UL1310, UL2367, UL508 |
|
2480340000CB PROTECTOR 1077 2P C 10A ACDC |
1,880 |
|
Datasheet | MCB 1077 | Bulk | Active | DIN Rail | Thermal Magnetic | 10A | 480 V | 125 V | Lever | 2 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.