Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
106-M2-P10-0.8ACIR BRKR THRM 800MA 250VAC 48VDC |
2,258 |
|
Datasheet | 106 | Bulk | Active | Panel Mount | Thermal | 800mA | 240 V | 48 V | Push to Reset | 1 | - | - | CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
106-M2-P10-1.5ACIR BRKR THRM 1.5A 250VAC 48VDC |
3,280 |
|
Datasheet | 106 | Bulk | Active | Panel Mount | Thermal | 1.5A | 240 V | 48 V | Push to Reset | 1 | - | - | CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
106-M2-P30-1ACIR BRKR THRM 1A 250VAC 48VDC |
7,627 |
|
Datasheet | 106 | Bulk | Active | Panel Mount | Thermal | 1A | 240 V | 48 V | Push to Reset | 1 | - | - | CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
106-M2-P10-6ACIR BRKR THRM 6A 250VAC 48VDC |
2,293 |
|
Datasheet | 106 | Bulk | Active | Panel Mount | Thermal | 6A | 240 V | 48 V | Push to Reset | 1 | - | - | CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
PP15-1-5.00A-XXCIR BRKR MAG-HYDR 5A PUSH-PULL |
2,588 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | - | - | Push-Pull | 1 | - | - | - |
|
2480130000CB PROTECTOR 1077 1P C 15A ACDC |
4,059 |
|
Datasheet | MCB 1077 | Bulk | Active | DIN Rail | Thermal Magnetic | 15A | 277 V | 60 V | Lever | 1 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE |
|
1410-F110-P1F1-W14Q-10ACIR BRKR THRM 10A 250VAC 48VDC |
2,534 |
|
Datasheet | 1410-F1 | Bulk | Active | Panel Mount | Thermal | 10A | 250 V | 48 V | Rocker | 1 | Red | - | CSA C22.2 No 235, UL1077 |
|
CR15-52-3.00A-39390-3-VCIR BRKR MAG-HYDR ROCKER |
3,077 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 3A | - | 80 V | Rocker | 1 | None | - | - |
|
CR15-52-10.0A-39390-10-VCIR BRKR MAG-HYDR ROCKER |
6,493 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | - | 80 V | Rocker | 1 | None | - | - |
|
4230-T120-K0CE-15ACIR BRKR THERM 15A 480VAC/125VDC |
6,864 |
|
Datasheet | 4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 15A | 480 V | 125 V | Lever | 2 | None | - | CSA C22.2 No 235, UL1077 |
|
7940102582CIR BRKR MAG-HYDR 15A 120VAC |
4,840 |
|
Datasheet | 9926 | Box | Active | DIN Rail | Magnetic (Hydraulic Delay) | 15A | 120 V | - | Lever | 1 | - | - | CE, CSA C22.2 No 5-02, UL489, VDE |
|
3120-N311-P7T1-W01D-5ACIR BRKR THRM 5A 250VAC 50VDC |
9,608 |
|
Datasheet | 3120-N | Box | Active | Panel Mount | Thermal | 5A | 415 V | 50 V | Rocker | 1 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
4230-T110-K0CU-50ACIR BRK THERM-M 50A 240VAC/60VDC |
1,997 |
|
Datasheet | 4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 50A | 277 V | 60 V | Lever | 1 | None | - | CSA C22.2 No 235, UL489 |
|
1110-F112-P1M1-3ACIR BRKR THRM 3A 250VAC 50VDC |
7,521 |
|
Datasheet | 1110 | Bulk | Active | Panel Mount | Thermal | 3A | 250 V | 50 V | Push-Push | 1 | None | - | CSA C22.2 No 235, IEC 60934, UL1077 |
|
1019930CIRCUIT BREAKER 1A |
1,978 |
|
Datasheet | TMC 7 | Box | Active | DIN Rail | Thermal Magnetic | 1A | 277 V | 125 V | Lever | 2 | None | - | cULus, UL1077 |
|
1019941CIRCUIT BRAKER 15A |
6,782 |
|
Datasheet | TMC 7 | Box | Active | DIN Rail | Thermal Magnetic | 15A | 277 V | 125 V | Lever | 2 | None | - | cULus, UL1077 |
|
1020001CIRCUIT BRAKER 8A |
9,346 |
|
Datasheet | TMC 7 | Box | Active | DIN Rail | Thermal Magnetic | 8A | 277 V | 125 V | Lever | 2 | None | - | cULus, UL1077 |
|
2478750000CB MCB 489 1P D 40A ACDC |
2,090 |
|
Datasheet | MCB 489 | Bulk | Active | DIN Rail | Thermal Magnetic | 40A | 120 V | 60 V | Lever | 1 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
2478540000CB MCB 489 1P D 1A ACDC |
4,575 |
|
Datasheet | MCB 489 | Bulk | Active | DIN Rail | Thermal Magnetic | 1A | 277 V | 60 V | Lever | 1 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
2478760000CB MCB 489 1P D 50A ACDC |
8,386 |
|
Datasheet | MCB 489 | Bulk | Active | DIN Rail | Thermal Magnetic | 50A | 120 V | 60 V | Lever | 1 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.