| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
QGA32110MOLDED CASE CIRCUIT BREAKER 240V |
9,160 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 110A | - | - | Lever | 3 | None | - | CSA, UL |
|
QGA32150MOLDED CASE CIRCUIT BREAKER 240V |
9,902 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 150A | 240 V | - | Lever | 3 | None | - | CSA, UL |
|
QGA32200MOLDED CASE CIRCUIT BREAKER 240V |
4,028 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 200A | 240 V | - | Lever | 3 | None | - | CSA, UL |
|
QGA32070MOLDED CASE CIRCUIT BREAKER 240V |
4,434 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 70A | - | - | Lever | 3 | None | - | CSA, UL |
|
QGA32175MOLDED CASE CIRCUIT BREAKER 240V |
8,089 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 175A | 240 V | - | Lever | 3 | None | - | CSA, UL |
|
QGA32100MOLDED CASE CIRCUIT BREAKER 240V |
9,141 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 100A | 240 V | - | Lever | 3 | None | - | CSA, UL |
|
QGA32225MOLDED CASE CIRCUIT BREAKER 240V |
3,439 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 225A | 240 V | - | Lever | 3 | None | - | CSA, UL |
|
QGA32090MOLDED CASE CIRCUIT BREAKER 240V |
3,775 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 90A | 240 V | - | Lever | 3 | None | - | CSA, UL |
|
3VA52117EC360AA0BRKR 3VA52 3P 110A 100KA FTAM AL |
6,556 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 110A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA, UL489 |
|
3VA52226EC322AA0BRKR 3VA52 3P 225A 65KA FTAM 100 |
3,456 |
|
Datasheet | 3VA5 | Bulk | Active | DIN Rail | - | 225A | 690 V | 750 V | Lever | 3 | None | - | UL |
|
3VA52256EC361AA0BRKR 3VA52 3P 250A 65KA FTAM NAV |
3,615 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 250A | 690 V | - | Lever | 3 | None | - | CCC, CE, UL489 |
|
3VA52226EC361AA0BRKR 3VA52 3P 225A 65KA FTAM NAV |
5,705 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 225A | 690 V | - | Lever | 3 | None | - | CCC, CE, UL489 |
|
BDL46080LUMOLDED CASE CIRCUIT BRKR 600Y/34 |
7,680 |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 80A | 525 V | - | Toggle | 4 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
JTMP-4-1RLS4R-38844-800SCIR BRKR MAG-HYDR LEVER |
3,286 |
|
Datasheet | JTMP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 4 | - | - | - |
|
8536SEO1V02B60SSTARTER 600VAC 90AMP NEMA +OPTIO |
7,389 |
|
Datasheet | - | Box | Obsolete | Chassis Mount | Manual Motor Starter | 90A | 600 V | - | Not Included | 3 | None | - | CSA, UL |
|
HLF36050MOLDED CASE CIRCUIT BREAKER 600V |
9,091 |
|
Datasheet | - | Box | Obsolete | Chassis Mount | Thermal Magnetic | 50A | 600 V | - | Lever | 3 | None | - | - |
|
HLL36050MOLDED CASE CIRCUIT BREAKER 600V |
5,286 |
|
Datasheet | PowerPact | Box | Obsolete | Chassis Mount | Thermal Magnetic | 50A | 690 V | - | Toggle | 3 | None | - | CSA, UL |
|
HLL36020MOLDED CASE CIRCUIT BREAKER 600V |
5,157 |
|
Datasheet | PowerPact | Box | Obsolete | Chassis Mount | Thermal Magnetic | 20A | 690 V | - | Toggle | 3 | None | - | CSA, UL |
|
HLL36040MOLDED CASE CIRCUIT BREAKER 600V |
7,929 |
|
Datasheet | PowerPact | Box | Obsolete | Chassis Mount | Thermal Magnetic | 40A | 690 V | - | Toggle | 3 | None | - | CSA, UL |
|
HLL36035MOLDED CASE CIRCUIT BREAKER 600V |
6,173 |
|
Datasheet | PowerPact | Box | Obsolete | Chassis Mount | Thermal Magnetic | 35A | 690 V | - | Toggle | 3 | None | - | CSA, IEC 60947-2, UL |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.