1410-F110-P1F1-W14Q-1ACIR BRKR THRM 1A 250VAC 48VDC |
5,418 |
|
Datasheet | 1410-F1 | Bulk | Active | Panel Mount | Thermal | 1A | 250 V | 48 V | Rocker | 1 | Red | - | CSA C22.2 No 235, UL1077 |
|
4435.0304CIR BRKR THRM 12A 240VAC 60VDC |
435 |
|
Datasheet | TA35 | Bulk | Active | Panel Mount | Thermal | 12A | 240 V | 60 V | Rocker | 2 | - | - | - |
|
4435.004CIR BRKR THRM 7A 240VAC 60VDC |
134 |
|
Datasheet | TA35 | Bulk | Active | Panel Mount | Thermal | 7A | 240 V | 60 V | Rocker | 2 | - | - | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
|
CPP11-52-4.00A-OC-VCIR BRKR MAG-HYDR 4A PUSH-PULL |
146 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 4A | - | 65 V | Push-Pull | 1 | None | - | UL489A |
|
4430.3047CIR BRKR THRM 7.5A 240VAC 60VDC |
170 |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | 7.5A | 240 V | 60 V | Rocker | 2 | - | - | - |
|
3-100-115CIR BRKR THRM 20A 240VAC/32VDC |
150 |
|
Datasheet | TA35 | Bag | Active | Panel Mount | Thermal | 20A | 240 V | 32 V | Rocker | 2 | - | - | - |
|
R11-2-30.0A-34972-1CIR BRKR 30A 125VAC 32VDC |
716 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 30A | 125 V | 32 V | Rocker | 1 | - | - | UL1077 |
|
BK/UCB-10CIRCUIT BREAKER AUTOMOTIVE |
123 |
|
Datasheet | UCB | Bulk | Active | Holder | - | 10A | - | 12 V | Automatic Reset | 1 | None | - | - |
|
4435.014CIR BRKR THRM 10A 240VAC 60VDC |
111 |
|
Datasheet | TA35 | Bulk | Active | Panel Mount | Thermal | 10A | 240 V | 60 V | Rocker | 2 | Green | 240V | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
|
4430.1328CIR BRKR THRM 15A 240VAC 60VDC |
245 |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | 15A | 240 V | 60 V | Rocker | 2 | - | - | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
|
|
4430.242CIR BRKR THRM 12A 240VAC 60VDC |
225 |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | 12A | 240 V | 60 V | Rocker | 2 | - | - | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
|
1110-F112-P1M1-6ACIR BRKR THRM 6A 250VAC 50VDC |
495 |
|
Datasheet | 1110 | Bulk | Active | Panel Mount | Thermal | 6A | 250 V | 50 V | Push-Push | 1 | None | - | CSA C22.2 No 235, IEC 60934, UL1077 |
|
4430.2351CIR BRKR THRM 15A 240VAC 60VDC |
270 |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | 15A | 240 V | 60 V | Rocker | 2 | - | - | - |
|
1D8UMCIR BRKR THRM-MAG 8A LEVER |
200 |
|
Datasheet | V-EA | Bulk | Active | DIN Rail | Thermal Magnetic | 8A | 480 V | 42 V | Lever | 1 | None | - | CSA, UL508, VDE |
|
4430.2051CIR BRKR THRM 20A 240VAC 60VDC |
118 |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | 20A | 240 V | 60 V | Rocker | 2 | Green | 220V | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
|
3120-N521-P7T1-W01D-12ACIR BRKR THERM SWITCH 2P |
1,855 |
|
Datasheet | 3120-N | Bulk | Active | Panel Mount | Thermal | 12A | 415 V | 50 V | Rocker | 2 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
|
W67-X2Q12-3CIR BRKR MAG-HYDR 3A 277VAC |
133 |
|
Datasheet | W6 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 3A | 277 V | - | Lever | 1 | - | - | - |
|
PP21-2-15.0A-OA-SCIR BRKR 15A 250VAC 65VDC |
320 |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | 250 V | 65 V | Push-Pull Plunger | 2 | - | - | UL1077 |
|
GMB631PC60CIR BRK THERM-M 60A 240VAC/60VDC |
189 |
|
Datasheet | GMB63 | Box | Active | DIN Rail | Thermal Magnetic | 60A | 240 V | 60 V | Lever | 1 | None | - | CSA C22.2 No 5, IEC 60947-2, UL489 |
|
4230-T130-K0CE-15ACIR BRKR THERM 15A 480VAC/125VDC |
137 |
|
Datasheet | 4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 15A | 480 V | 125 V | Lever | 3 | None | - | CSA C22.2 No 235, UL1077 |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.