JIEXIN Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Circuit Breakers

Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal) Approval Agency
M55629/5-325L Sensata-Airpax

M55629/5-325L

CIR BRKR HYD MAG

Sensata-Airpax

4,390
Datasheet - Bulk Obsolete - - - - - - - - - -
M55629/5-346L Sensata-Airpax

M55629/5-346L

CIR BRKR HYD MAG

Sensata-Airpax

2,172
Datasheet - Bulk Obsolete - - - - - - - - - -
M55629/5-367L Sensata-Airpax

M55629/5-367L

CIR BRKR HYD MAG

Sensata-Airpax

3,691
Datasheet - Bulk Obsolete - - - - - - - - - -
M55629/5-388L Sensata-Airpax

M55629/5-388L

CIR BRKR HYD MAG

Sensata-Airpax

9,939
Datasheet - Bulk Obsolete - - - - - - - - - -
M55629/5-418L Sensata-Airpax

M55629/5-418L

CIR BRKR HYD MAG

Sensata-Airpax

4,624
Datasheet - Bulk Obsolete - - - - - - - - - -
M55629/5-382L Sensata-Airpax

M55629/5-382L

CIR BRKR HYD MAG

Sensata-Airpax

7,300
Datasheet - Bulk Obsolete - - - - - - - - - -
M55629/5-383L Sensata-Airpax

M55629/5-383L

CIR BRKR HYD MAG

Sensata-Airpax

4,632
Datasheet - Bulk Obsolete - - - - - - - - - -
M55629/5-402L Sensata-Airpax

M55629/5-402L

CIR BRKR HYD MAG

Sensata-Airpax

7,258
Datasheet - Bulk Active - - - - - - - - - -
HDA36025 Schneider Electric

HDA36025

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

4,394
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 25A 690 V - Toggle 3 None - CSA, UL
HDA36020 Schneider Electric

HDA36020

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

6,198
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 20A 690 V - Toggle 3 None - CSA, IEC 60947-2, UL
HDA36015 Schneider Electric

HDA36015

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

7,810
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 15A 690 V - Toggle 3 None - CSA, UL
HDA36030 Schneider Electric

HDA36030

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

2,454
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 30A 690 V - Toggle 3 None - CSA, UL
HDA36045 Schneider Electric

HDA36045

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

2,839
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 45A 690 V - Toggle 3 None - CSA, UL
HDA36040 Schneider Electric

HDA36040

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

4,836
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 40A 690 V - Toggle 3 None - CSA, UL
HDA36060 Schneider Electric

HDA36060

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

5,663
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 60A 690 V - Toggle 3 None - CSA, UL
HDA36035 Schneider Electric

HDA36035

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

3,807
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 35A 690 V 250 V Toggle 3 None - CSA, UL
AP16-32740-2 Sensata-Airpax

AP16-32740-2

CIR BRKR HYD MAG

Sensata-Airpax

8,048
Datasheet - Bulk Active - - - - - - - - - -
3VA51106EC321AA0 Siemens

3VA51106EC321AA0

BRKR 3VA51 3P 100A 65KA FTAM NAV

Siemens

2,818
Datasheet SENTRON Box Active DIN Rail - 100A 690 V - Lever 3 None - CCC, UL489
3VA52101BB310AA0 Siemens

3VA52101BB310AA0

MCSW 3VA52 3P 100A 100KA

Siemens

3,945
Datasheet SENTRON Box Active DIN Rail - 100A 690 V - Lever 3 None - CCC, CE, CSA, EAC, UL489, VDE
AP12-4-50-401 Sensata-Airpax

AP12-4-50-401

CIR BRKR HYD MAG

Sensata-Airpax

9,275
Datasheet AP Bulk Active Panel Mount Magnetic (Hydraulic Delay) 400mA 240 V 50 V Toggle 2 None - CSA, UL1077
Total 59416 Record«Prev1... 24032404240524062407240824092410...2971Next»
FAQ

Frequently Asked Questions

What are Circuit Breakers components used for?

Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Circuit Breakers part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Circuit Breakers?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top