Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BDA260404MOLDED CASE CIRCUIT BRKR 600Y/34 |
2,308 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 40A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA260304MOLDED CASE CIRCUIT BRKR 600Y/34 |
7,163 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 30A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA260604MOLDED CASE CIRCUIT BRKR 600Y/34 |
2,892 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 60A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA260602MOLDED CASE CIRCUIT BRKR 600Y/34 |
6,971 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 60A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA260302MOLDED CASE CIRCUIT BRKR 600Y/34 |
8,181 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 30A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA260202MOLDED CASE CIRCUIT BRKR 600Y/34 |
9,991 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 20A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA260151MOLDED CASE CIRCUIT BRKR 600Y/34 |
7,413 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 15A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
2510MBW2MANUAL STARTER 600VAC |
5,092 |
|
Datasheet | M | Box | Active | Chassis Mount | Manual Motor Starter | 18A | 600 V | - | Pushbutton | 3 | None | - | CSA, UL |
|
2510MBW12MANUAL STARTER 600VAC |
9,224 |
|
Datasheet | M | Box | Active | Chassis Mount | Manual Motor Starter | 18A | 600 V | - | Pushbutton | 3 | None | - | CSA, UL |
|
3VA51126ED110AA0BRKR 3VA51 1P 125A 50KA FTFM |
4,842 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 125A | 415 V | - | Lever | 1 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
FT2-B2-24-825-11A-BACIRCUIT BREAKER |
2,541 |
|
Datasheet | F | Bulk | Active | Chassis Mount | Magnetic (Hydraulic Delay) | 250A | 277 V | 125 V | Lever | 2 | None | - | - |
|
FT2-B2-22-810-11A-BACIRCUIT BREAKER |
4,177 |
|
Datasheet | F | Bulk | Active | Chassis Mount | Magnetic (Hydraulic Delay) | 100A | 277 V | 125 V | Lever | 2 | None | - | - |
|
BDA260402MOLDED CASE CIRCUIT BREAKER 600Y |
3,264 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 40A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA260401MOLDED CASE CIRCUIT BRKR 600Y/34 |
9,788 |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 40A | 525 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
QOB3305252MINIATURE CIRCUIT BREAKER 240V 3 |
5,150 |
|
Datasheet | QO | Box | Obsolete | Chassis Mount | Thermal Magnetic | 30A | - | - | Lever | 3 | None | - | CSA, UL |
|
3VA51955ED321AA0BRKR 3VA51 3P 15A 35KA FTFM NAV |
2,386 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 15A | 690 V | - | Lever | 3 | None | - | CCC, UL489 |
|
3VA51104EC311AA0BRKR 3VA51 3P 100A 25KA FTAM NAV |
2,478 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 100A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
EJB14070MINIATURE CIRCUIT BREAKER 277V 7 |
3,236 |
|
Datasheet | - | Box | Obsolete | Chassis Mount | Thermal Magnetic | 70A | - | - | Lever | 1 | None | - | cULus |
|
3VA51104ED261AA0BRKR 3VA51 2P 100A 25KA FTFM NAV |
6,745 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 100A | 415 V | - | Lever | 2 | None | - | CCC, CE, UL489, VDE |
|
3VA51114ED221AA0BRKR 3VA51 2P 110A 25KA FTFM NAV |
6,016 |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 110A | 415 V | - | Lever | 2 | None | - | CCC, UL489 |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.