Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
299-3-40703-219CIR BRKR,HYDMAG |
3,858 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
299-3-40703-223CIR BRKR,HYDMAG |
3,429 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
209-3-41214-100-VCIR BRKR HYD MAG |
3,569 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
A9N18502ACTI9 C120H MCB 2P D 100A 15000A |
5,557 |
|
Datasheet | C120 | Box | Active | DIN Rail | Thermal Magnetic | 100A | 415 V | - | Toggle | 2 | None | - | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
|
A9N18413ACTI9 C120H MCB 2P B 80A 15000A |
7,081 |
|
Datasheet | C120 | Box | Active | DIN Rail | Thermal Magnetic | 80A | 415 V | - | Toggle | 2 | None | - | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
|
A9N18457ACTI9 C120H MCB 2P C 80A 15000A |
8,734 |
|
Datasheet | Acti9 | Box | Active | DIN Rail | Thermal Magnetic | 80A | 415 V | - | Toggle | 2 | None | - | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
|
A9N18458ACTI9 C120H MCB 2P C 100A 15000A |
4,429 |
|
Datasheet | Acti9 | Box | Active | DIN Rail | Thermal Magnetic | 100A | 415 V | 250 V | Toggle | 2 | None | - | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
|
A9N18414ACTI9 C120H MCB 2P B 100A 15000A |
9,942 |
|
Datasheet | C120 | Box | Active | DIN Rail | Thermal Magnetic | 100A | 415 V | - | Toggle | 2 | None | - | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
|
A9N18501ACTI9 C120H MCB 2P D 80A 15000A |
2,424 |
|
Datasheet | C120 | Box | Active | DIN Rail | Thermal Magnetic | 80A | 415 V | - | Toggle | 2 | None | - | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
|
A6X30113714CIRCUIT-BREAKER SCREW CONNECTION |
4,294 |
|
Datasheet | SIRIUS | Box | Active | DIN Rail | Thermal Magnetic | 32A | 690 V | - | Rotary | 3 | None | - | - |
|
3RV24214AA15MSP S0 FOR XFRMR 11-16A AUX 1NO+ |
4,199 |
|
Datasheet | SIRIUS | Box | Active | DIN Rail | Thermal Magnetic | 16A | 690 V | - | Rotary | 3 | None | - | CCC, CE, CSA, EAC, UL, VDE |
|
3RV24214BA15MSP S0 FOR XFRMR 14-20A AUX 1NO+ |
6,114 |
|
Datasheet | SIRIUS | Box | Active | DIN Rail | Thermal Magnetic | 20A | 690 V | - | Rotary | 3 | None | - | CCC, CE, CSA, EAC, UL, VDE |
|
219-3-2REC4-66-8-8M-7-ACIR BRKR MAG-HYDR LEVER |
7,972 |
|
Datasheet | 219 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 7A | 480 V | - | Lever | 3 | None | - | - |
|
IELHK3111-26761-1-VCIRCUIT BREAKER MAG-HYDR LEVER |
3,517 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | - | - | - | - |
|
IULK211-38479-100CIRCUIT BREAKER MAG-HYDR LEVER |
7,672 |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | - | - | - | - |
|
IELK1111-31311-1-VCIRCUIT BREAKER MAG-HYDR LEVER |
9,809 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 4 | - | - | - |
|
IELK1111-31311-2-VCIRCUIT BREAKER MAG-HYDR LEVER |
8,030 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 4 | - | - | - |
|
IELZX111-2REG4-61-40.0-03-VCIR BRKR HYD MAG |
8,721 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 40A | 480 V | 80 V | Rocker | 3 | None | - | CCC, CSA, UL1077, VDE |
|
GV2L04TESYS MAGNETIC CIRCUIT BREAKER |
9,519 |
|
Datasheet | TeSys | Box | Active | DIN Rail | Magnetic | 630mA | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
|
GA3-B1-26-612-1B-HCCIRCUIT BREAKER |
3,431 |
|
Datasheet | G | Bulk | Active | DIN Rail | Magnetic (Hydraulic Delay) | 12A | 480 V | 125 V | Lever | 3 | None | - | CCC, UL |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.