JIEXIN Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Circuit Breakers

Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal) Approval Agency
BDL36040 Schneider Electric

BDL36040

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

4,113
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 40A 600 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDL36080 Schneider Electric

BDL36080

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

1,273
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 80A 600 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDL36100 Schneider Electric

BDL36100

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

1,024
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 100A 600 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDL36070 Schneider Electric

BDL36070

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

4,300
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 70A 600 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
HDL36090 Schneider Electric

HDL36090

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

1,632
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 90A 690 V 250 V Toggle 3 None - CSA, UL
HDL36070 Schneider Electric

HDL36070

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

1,431
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 70A 690 V 250 V Toggle 3 None - CSA, UL
HDL36100 Schneider Electric

HDL36100

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

1,254
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 100A 600 V 250 V Toggle 3 None - CSA, UL
BGL36030 Schneider Electric

BGL36030

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

2,795
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 30A 120 V 250 V Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BGL36050 Schneider Electric

BGL36050

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

2,226
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 50A 525 V - Toggle 3 None - EN 60947-2, IEC 60947-2
BGL36020 Schneider Electric

BGL36020

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

2,679
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 20A 120 V 250 V Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BGL36015 Schneider Electric

BGL36015

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

1,719
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 15A 525 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BGL36060 Schneider Electric

BGL36060

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

4,806
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 60A 525 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
HJL36050M72 Schneider Electric

HJL36050M72

MOTOR CIRCUIT PROTECTOR 600V 50A

Schneider Electric

3,555
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 50A 690 V 500 V Toggle 3 None - CSA, UL
HGL36060 Schneider Electric

HGL36060

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

4,979
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 60A 690 V 500 V Toggle 3 None - CSA, UL
HGL36030 Schneider Electric

HGL36030

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

4,135
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 30A 600 V 250 V Toggle 3 None - CSA, UL
HGL36020 Schneider Electric

HGL36020

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

4,736
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 20A 600 V 250 V Toggle 3 None - CSA, UL
HGL36040 Schneider Electric

HGL36040

MOLDED CASE CIRCUIT BREAKER 600V

Schneider Electric

2,278
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 40A 600 V 250 V Toggle 3 None - CSA, UL
BDL36110 Schneider Electric

BDL36110

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

4,180
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 110A 525 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BGL36100 Schneider Electric

BGL36100

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

3,621
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 100A 525 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
HJL36100M73 Schneider Electric

HJL36100M73

MOTOR CIRCUIT PROTECTOR 600V 100

Schneider Electric

1,068
Datasheet PowerPact Box Active Chassis Mount Thermal Magnetic 100A 690 V - Toggle 3 None - CSA, UL
Total 59416 Record«Prev1... 196197198199200201202203...2971Next»
FAQ

Frequently Asked Questions

What are Circuit Breakers components used for?

Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Circuit Breakers part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Circuit Breakers?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top