Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
M55629/1-393LCIR BRKR HYD MAG |
3,167 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 25A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-351LCIR BRKR HYD MAG |
8,056 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 8A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-361LCIR BRKR HYD MAG |
4,782 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 9A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-396LCIR BRKR HYD MAG |
5,743 |
|
Datasheet | AP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 25A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-416LCIR BRKR HYD MAG |
4,369 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 40A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-409LCIR BRKR HYD MAG |
2,615 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 35A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-367LCIR BRKR HYD MAG |
5,968 |
|
Datasheet | AP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-414LCIR BRKR HYD MAG |
3,998 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 40A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-380LCIR BRKR HYD MAG |
8,084 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 15A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-379LCIR BRKR HYD MAG |
2,429 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 15A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-401LCIR BRKR HYD MAG |
9,891 |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 30A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M55629/1-311LCIR BRKR HYD MAG |
8,171 |
|
Datasheet | AP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 3A | 240 V | 50 V | Lever | 1 | None | - | - |
|
M9F43225MULTI9 C60BP 2P D 25A 10KA 480Y/ |
9,181 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 25A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
|
M9F43208MULTI9 C60BP 2P D 8A 10KA 480Y/2 |
3,394 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 8A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
|
M9F42220MULTI9 C60BP 2P C 20A 10KA 480Y/ |
3,427 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 20A | 415 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
|
M9F43206MULTI9 C60BP 2P D 6A 10KA 480Y/2 |
4,955 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 6A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
|
M9F42208MULTI9 C60BP 2P C 8A 10KA 480Y/2 |
4,494 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 8A | 415 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
|
M9F43215MULTI9 C60BP 2P D 15A 10KA 480Y/ |
5,603 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 15A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
|
M9F43220MULTI9 C60BP 2P D 20A 10KA 480Y/ |
4,536 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 20A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
|
M9F43210MULTI9 C60BP 2P D 10A 10KA 480Y/ |
3,870 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 10A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, GB 14048.2, IEC 60947-2, UL489 |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.