Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EA2-B0-64-663-22A-DICIRCUIT BREAKER |
6,976 |
|
Datasheet | E | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 63A | 240 V | 125 V | Lever | 2 | None | - | - |
|
EA2-B0-64-810-22A-DICIRCUIT BREAKER |
9,162 |
|
Datasheet | E | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 100A | 240 V | 125 V | Lever | 2 | None | - | - |
|
EA2-B0-64-685-22A-DICIRCUIT BREAKER |
6,880 |
|
Datasheet | E | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 85A | 240 V | 125 V | Lever | 2 | None | - | - |
|
8345-B03A-L6M1-DB1B1B-50ACIR BRKR THRM 50A |
4,916 |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 50A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
J33-B0-42-620-87A-CGCIRCUIT BREAKER |
9,939 |
|
Datasheet | J | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 240 V | - | Rocker | 3 | None | - | cULus, UL489 |
|
219-2-38431-1CIR BRKR MAG-HYDR |
8,947 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IULHK111-30468-20CIR BRKR,HYDMAG |
4,919 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IULHK22-35534-80CIRCUIT BREAKER MAG-HYDR LEVER |
3,755 |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | - | - | - | - |
|
A9R12240ACTI9 IID 2P 40A 100MA AC RCCB |
2,017 |
|
Datasheet | Acti9 | Box | Active | DIN Rail | Magnetic | 100mA | 240 V | - | Toggle | 2 | None | - | EN 61008-1, IEC 61008-1 |
|
BA4-B0-24-615-121-DCIRCUIT BREAKER |
4,822 |
|
Datasheet | B | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | 250 V | 80 V | Lever | 4 | None | - | CCC, CSA, UL, VDE |
|
BA4-B0-26-616-12A-DCIRCUIT BREAKER |
8,061 |
|
Datasheet | B | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 16A | 250 V | 80 V | Lever | 4 | None | - | CCC, CSA, UL, VDE |
|
CG2-B2-24-685-311-CCIRCUIT BREAKER |
7,838 |
|
Datasheet | C | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 85A | 480 V | 150 V | Rocker | 2 | None | - | CCC, CSA, UL |
|
IALDHK111-40344-1CIRCUIT BREAKER |
5,010 |
|
Datasheet | IAL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 1A | 240 V | 50 V | Rocker | 3 | None | - | CSA, TUV, UL1077, VDE |
|
IULHK111-71263-1CIR BRKR,HYDMAG |
7,533 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
3RV23214AC10CIRCUIT-BREAKER S0 16A NO OVERLO |
4,639 |
|
Datasheet | SIRIUS | Box | Active | DIN Rail | Magnetic | 16A | 690 V | - | Rotary | 3 | None | - | CCC, CE, CSA, EAC, UL, VDE |
|
3RV23214BC20CIRCUIT-BREAKER S0 20A NO OVERLO |
6,593 |
|
Datasheet | SIRIUS | Box | Active | DIN Rail | Magnetic | 20A | 690 V | - | Rotary | 3 | None | - | CCC, CE, CSA, EAC, UL, VDE |
|
219-2-3191-00CIRCUIT BREAKER MAG-HYDR LEVER |
9,051 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
QOU215VH5283MINIATURE CIRCUIT BREAKER 120/24 |
7,476 |
|
Datasheet | QOU | Box | Active | Chassis Mount | Thermal Magnetic | 15A | 240 V | - | Lever | 2 | None | - | CSA, IEC, UL |
|
203-1-1-66F-252-L-1CIR BRKR MAG 2.5A 32VDC ROCKER |
8,227 |
|
Datasheet | 203 | Bulk | Not For New Designs | Panel Mount | Magnetic | 2.5A | - | 32 V | Rocker | 1 | - | - | UL1077 |
|
LELBXK111-34720-20CIR BRKR,HYDMAG |
8,709 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.