Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
279-2-1REC4-53F-9-9-10CIR BRKR HYD MAG |
2,711 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
279-2-1REC4-53F-9-9-20CIR BRKR HYD MAG |
2,963 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
79401140082210-T230-K0M1-H321 2A |
4,685 |
|
Datasheet | * | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - |
|
9923200002CB2213-10 20A W/O AUX |
4,534 |
|
Datasheet | * | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - |
|
BA3-B0-46-620-111-DCIRCUIT BREAKER |
6,615 |
|
Datasheet | B | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 250 V | 80 V | Lever | 3 | None | - | CCC, CSA, UL, VDE |
|
229-2-1RS4-40683-2.5CIR BRKR MAG-HYDR |
9,476 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
N32-B0-24-620-122-C3CIRCUIT BREAKER |
9,534 |
|
Datasheet | N | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 240 V | - | Push to Reset | 2 | None | - | TUV, UL489 |
|
IALHK111-1REC4-71211-12CIR BRKR MAG-HYDR |
9,241 |
|
Datasheet | IAL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | 415 V | 80 V | Lever | 3 | None | - | - |
|
IELHK111-1REC5-71165-3-VCIR BRKR,HYDMAG |
7,604 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IELHK111-1REC5-71165-4-VCIR BRKR,HYDMAG |
8,296 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
MMSKG1AGMANUAL SWITCH,TOGGLE,2-P,115VAC, |
8,670 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
A9F84116ACTI9 IC60H 1P C 16A MCB |
8,464 |
|
Datasheet | - | Box | Active | DIN Rail | Thermal Magnetic | 16A | 500 V | - | Toggle | 1 | None | - | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
|
203-1-2598-1CIR BRKR ROCKER |
6,307 |
|
Datasheet | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | UL1077 |
|
M9F23213MULTI9 C60SP 2P D 13A 10KA 480Y/ |
4,146 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 13A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 235, EN 60947-2, GB 14048.2, IEC 60947-2, UL1077 |
|
M9F23204MULTI9 C60SP 2P D 4A 10KA 480Y/2 |
7,811 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 4A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 235, EN 60947-2, GB 14048.2, IEC 60947-2, UL1077 |
|
M9F23206MULTI9 C60SP 2P D 6A 10KA 480Y/2 |
8,615 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 6A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 235, EN 60947-2, GB 14048.2, IEC 60947-2, UL1077 |
|
M9F23205MULTI9 C60SP 2P D 5A 10KA 480Y/2 |
9,644 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 5A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 235, EN 60947-2, GB 14048.2, IEC 60947-2, UL1077 |
|
M9F23202MULTI9 C60SP 2P D 2A 10KA 480Y/2 |
4,374 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 2A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 235, EN 60947-2, GB 14048.2, IEC 60947-2, UL1077 |
|
M9F23203MULTI9 C60SP 2P D 3A 10KA 480Y/2 |
6,937 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 3A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 235, EN 60947-2, GB 14048.2, IEC 60947-2, UL1077 |
|
M9F22206MULTI9 C60SP 2P C 6A 10KA 480Y/2 |
3,567 |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 6A | 440 V | - | Toggle | 2 | None | - | CSA C22.2 No 235, EN 60947-2, GB 14048.2, IEC 60947-2, UL1077 |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.