Circuit Breakers
Explore Circuit Breakers parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
3120-N324-P7T1-W19DG4-5ACIR BRKR THRM SWITCH 5A IP65 |
3,770 |
|
Datasheet | 3120-N | Box | Active | Panel Mount | Thermal | 5A | 415 V | 50 V | Rocker | 2 | Green | 230V | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
3-150-707TA35 CIRCUIT BREAKER 2P 16A F2 |
2,241 |
|
Datasheet | TA35 | Box | Active | Panel Mount | Thermal Magnetic | 16A | 240 V | 32 V | Rocker | 2 | Green | - | CSA C22.2 No 235, GB 17701, IEC 60934, IEC 62368-1, UL1077 |
|
3-150-708TA35 CIRCUIT BREAKER 2P 16A T2 |
3,451 |
|
Datasheet | TA35 | Box | Active | Panel Mount | Thermal Magnetic | 16A | 240 V | 32 V | Rocker | 2 | Green | - | CSA C22.2 No 235, GB 17701, IEC 60934, IEC 62368-1, UL1077 |
|
IPA-6-1REG4-52-.500-01CIR BRKR MAG-HYDR LEVER .5A |
1,121 |
|
Datasheet | IPA | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 500mA | - | - | Lever | 1 | - | - | - |
|
|
IELK1-1-62-20.0-01-VCIR BRKR MAG-HYDR LEVER 20A |
2,885 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 250 V | - | Lever | 1 | None | - | UL1077 |
|
IELK1-1-72-25.0-01-VCIR BRKR MAG-HYDR LEVER 25A |
1,359 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 25A | 250 V | 80 V | Lever | 1 | None | - | UL1077 |
|
IELK1-1-52-5.00-01-VCIR BRKR MAG-HYDR |
1,845 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 415 V | 80 V | Lever | 1 | None | - | - |
|
IELK1-1-62-5.00-01-VCIR BRKR MAG-HYDR |
3,796 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 415 V | 80 V | Lever | 1 | None | - | - |
|
IELK1-1-52-50.0-01-VCIR BRKR MAG-HYDR LEVER 50A |
3,299 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 50A | - | - | Lever | 1 | - | - | - |
|
IELK1-1-62-20.0-91-VCIR BRKR MAG-HYDR LEVER 20A |
4,133 |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 250 V | - | Lever | 1 | None | - | UL1077 |
|
IULK1-1-62-20.0-01CIR BRKR MAG-HYDR 20A LEVER |
1,767 |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | - | - | Lever | 1 | - | - | - |
|
IULK1-1-66-15.0-01CIR BRKR MAG-HYDR |
3,436 |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | 250 V | 80 V | Lever | 1 | None | - | - |
|
IULK1-1-72-30.0-01CIR BRKR MAG-HYDR |
2,878 |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 7.5A | 250 V | 80 V | Lever | 1 | None | - | - |
|
IULK1-1-72-20.0-01CIR BRKR MAG-HYDR 20A LEVER |
1,769 |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | - | - | Lever | 1 | - | - | - |
|
2800924CIR BRKR SOLID STATE 3A 24VDC |
1,097 |
|
Datasheet | CB | Bulk | Active | Holder | Solid State | 3A | - | 24 V | - | 1 | - | - | - |
|
2800908CIR BRKR SOLID STATE 1A 24VDC |
1,146 |
|
Datasheet | CB | Bulk | Active | Holder | Solid State | 1A | - | 24 V | - | 1 | - | - | - |
|
2800927CIR BRKR SOLID STATE |
4,136 |
|
Datasheet | - | Bulk | Active | Holder | Solid State | 8A | - | 24 V | Slide Switch | 1 | - | - | - |
|
2800906CB E1 24DC/8A NO P |
2,373 |
|
Datasheet | - | Bulk | Active | Panel Mount | Thermal Magnetic | 8A | - | 24 V | Push to Reset | 1 | - | - | - |
|
5SY41036CIRCUIT BREAKER 10KA 1POLE B3 |
1,340 |
|
Datasheet | 5SY4 | Bulk | Active | DIN Rail | - | - | 400 V | 72 V | Lever | 1 | None | - | CCC, EAC, IMQ, UR, VDE |
|
4430.2781CIR BRKR THRM 240VAC 60VDC |
2,541 |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | - | 240 V | 60 V | Rocker | 2 | - | - | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
Frequently Asked Questions
What are Circuit Breakers components used for?
Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Circuit Breakers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.