Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal) Approval Agency
AD2-B0-34-450-3A2-C Carling Technologies

AD2-B0-34-450-3A2-C

CIRCUIT BREAKER

Carling Technologies

4,517
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 5A 277 V 80 V Rocker 2 None - CCC, CSA, UL
AD2-B0-34-615-5F2-C Carling Technologies

AD2-B0-34-615-5F2-C

CIRCUIT BREAKER

Carling Technologies

7,091
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 15A 277 V 80 V Rocker 2 None - CCC, CSA, UL
AJ2-B0-24-620-2C1-D Carling Technologies

AJ2-B0-24-620-2C1-D

CIRCUIT BREAKER

Carling Technologies

3,905
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 20A 250 V 80 V Rocker 2 None - CCC, CSA, UL, VDE
AD2-B0-34-620-5G1-C Carling Technologies

AD2-B0-34-620-5G1-C

CIRCUIT BREAKER

Carling Technologies

4,251
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 20A 277 V 80 V Rocker 2 None - CCC, CSA, UL
A42-B0-24-630-BC2-C Carling Technologies

A42-B0-24-630-BC2-C

CIRCUIT BREAKER

Carling Technologies

7,541
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 30A 277 V 80 V Rocker 2 None - CCC, CSA, UL
AJ2-B0-26-630-471-D Carling Technologies

AJ2-B0-26-630-471-D

CIRCUIT BREAKER

Carling Technologies

6,952
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 30A 250 V 80 V Rocker 2 None - CCC, CSA, UL, VDE
AD2-B0-24-615-552-D Carling Technologies

AD2-B0-24-615-552-D

CIRCUIT BREAKER

Carling Technologies

2,139
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 15A 250 V 80 V Rocker 2 None - CCC, CSA, UL, VDE
AF2-B0-34-450-331-C Carling Technologies

AF2-B0-34-450-331-C

CIRCUIT BREAKER

Carling Technologies

3,840
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 5A 277 V 80 V Rocker 2 None - CCC, CSA, UL
AC2-B0-34-650-531-C Carling Technologies

AC2-B0-34-650-531-C

CIRCUIT BREAKER

Carling Technologies

2,783
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 50A 277 V 80 V Rocker 2 None - CCC, CSA, UL
AD2-B0-24-460-552-D Carling Technologies

AD2-B0-24-460-552-D

CIRCUIT BREAKER

Carling Technologies

8,397
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 6A 250 V 80 V Rocker 2 None - CCC, CSA, UL, VDE
AD2-B0-34-640-5F2-C Carling Technologies

AD2-B0-34-640-5F2-C

CIRCUIT BREAKER

Carling Technologies

7,636
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 40A 277 V 80 V Rocker 2 None - CCC, CSA, UL
A32-B0-24-630-421-C Carling Technologies

A32-B0-24-630-421-C

CIRCUIT BREAKER

Carling Technologies

2,987
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 30A 277 V 80 V Rocker 2 None - CCC, CSA, UL
AC2-B0-24-425-431-D Carling Technologies

AC2-B0-24-425-431-D

CIRCUIT BREAKER

Carling Technologies

6,029
Datasheet A Bulk Active Panel Mount Magnetic (Hydraulic Delay) 2.5A 250 V 80 V Rocker 2 None - CCC, CSA, UL, VDE
413-K34-LN2-30A E-T-A

413-K34-LN2-30A

CIR BRKR THRM 30A 115VAC 28VDC

E-T-A

3,186
Datasheet 413 Bulk Active Panel Mount Thermal 30A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
IELH11-1REC4-70047-9-V Sensata-Airpax

IELH11-1REC4-70047-9-V

CIR BRKR,HYDMAG

Sensata-Airpax

3,842
Datasheet - Bulk Obsolete - - - - - - - - - -
413-K34-LN2-60A E-T-A

413-K34-LN2-60A

CIR BRKR THRM 60A 115VAC 28VDC

E-T-A

7,654
Datasheet 413 Bulk Active Panel Mount Thermal 60A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
413-K34-FN2-30A E-T-A

413-K34-FN2-30A

CIR BRKR THRM 30A 115VAC 28VDC

E-T-A

8,743
Datasheet 413 Bulk Active Panel Mount Thermal 30A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
413-K34-FN2-35A E-T-A

413-K34-FN2-35A

CIR BRKR THRM 35A 115VAC 28VDC

E-T-A

2,756
Datasheet 413 Bulk Active Panel Mount Thermal 35A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
413-K34-FN2-40A E-T-A

413-K34-FN2-40A

CIR BRKR THRM 40A 115VAC 28VDC

E-T-A

9,550
Datasheet 413 Bulk Active Panel Mount Thermal 40A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
413-K34-FN2-50A E-T-A

413-K34-FN2-50A

CIR BRKR THRM 50A 115VAC 28VDC

E-T-A

5,485
Datasheet 413 Bulk Active Panel Mount Thermal 50A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
Total 59416 Record«Prev1... 16231624162516261627162816291630...2971Next»
FAQ

Frequently Asked Questions

What are Circuit Breakers components used for?

Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Circuit Breakers part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Circuit Breakers?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top