Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal) Approval Agency
MG2-B-64-490-1-BB6-2-C Carling Technologies

MG2-B-64-490-1-BB6-2-C

CIRCUIT BREAKER

Carling Technologies

5,613
Datasheet M Bulk Active Panel Mount Magnetic (Hydraulic Delay) 9A 250 V 80 V Rocker 2 Neon 250V CCC, CSA, UL1077
8345-E01A-V3T1-DB1B1B-125A E-T-A

8345-E01A-V3T1-DB1B1B-125A

CIR BRKR THRM 125A

E-T-A

9,802
Datasheet 8345 Bulk Active Panel Mount Magnetic (Hydraulic Delay) 125A 480 V 80 V Lever 1 None - CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489
IERB1-1RS4C-70120-2-T Sensata-Airpax

IERB1-1RS4C-70120-2-T

CIR BRKR,HYDMAG

Sensata-Airpax

6,172
Datasheet - Bulk Obsolete - - - - - - - - - -
MD2-S-24-450-1-A35-B-C Carling Technologies

MD2-S-24-450-1-A35-B-C

CIRCUIT BREAKER

Carling Technologies

7,455
Datasheet M Bulk Active Panel Mount Magnetic (Hydraulic Delay) 5A 250 V 80 V Rocker 2 None - CCC, CSA, UL1077
MD2-S-24-630-1-A35-B-C Carling Technologies

MD2-S-24-630-1-A35-B-C

CIRCUIT BREAKER

Carling Technologies

8,758
Datasheet M Bulk Active Panel Mount Magnetic (Hydraulic Delay) 30A 250 V 80 V Rocker 2 None - CCC, CSA, UL1077
BA2-B0-36-610-12A-D Carling Technologies

BA2-B0-36-610-12A-D

CIRCUIT BREAKER

Carling Technologies

3,427
Datasheet B Bulk Active Panel Mount Magnetic (Hydraulic Delay) 10A 250 V 80 V Lever 2 None - CCC, CSA, UL, VDE
MD2-S-34-625-1-A35-B-C Carling Technologies

MD2-S-34-625-1-A35-B-C

CIRCUIT BREAKER

Carling Technologies

4,863
Datasheet M Bulk Active Panel Mount Magnetic (Hydraulic Delay) 25A 250 V 80 V Rocker 2 None - CCC, CSA, UL1077
9925650000 Weidmüller

9925650000

CIR BRKR 500MA 480VAC 110VDC

Weidmüller

4,033
Datasheet CB9100 Bulk Obsolete DIN Rail Thermal Magnetic 500mA 480 V 110 V Lever 2 - - -
9926263510 Weidmüller

9926263510

CIR BRKR MAG-HYDR 10A 480VAC

Weidmüller

3,576
Datasheet 9926 Bulk Active DIN Rail Magnetic (Hydraulic Delay) 10A 480 V - Lever 3 - - CE, CSA C22.2 No 235, UL1077, VDE
UPL2-26794-1 Sensata-Airpax

UPL2-26794-1

CIRCUIT BREAKER MAG-HYDR LEVER

Sensata-Airpax

3,781
Datasheet UPL Bulk Obsolete Panel Mount Magnetic (Hydraulic Delay) - - - Lever - - - -
IEGZX66-37472-1530-V Sensata-Airpax

IEGZX66-37472-1530-V

CIR BRKR,HYDMAG

Sensata-Airpax

6,177
Datasheet - Bulk Active - - - - - - - - - -
483-G411-K1M1-A1S0Z-7.5A E-T-A

483-G411-K1M1-A1S0Z-7.5A

CIR BRKR THRM 7.5A 115VAC 28VDC

E-T-A

9,543
Datasheet 483 Bulk Active Panel Mount Thermal 7.5A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
483-G411-K1M1-A1S0ZN-30A E-T-A

483-G411-K1M1-A1S0ZN-30A

CIR BRKR THRM 30A 115VAC 28VDC

E-T-A

3,185
Datasheet 483 Bulk Active Panel Mount Thermal 30A 115 V 28 V Push-Pull Plunger 1 None - CSA C22.2 No 235, UL1077
IAGN1-1REG4-59-7.50 Sensata-Airpax

IAGN1-1REG4-59-7.50

CIR BRKR MAG-HYDR LEVER

Sensata-Airpax

9,298
Datasheet IAG Bulk Active Panel Mount Magnetic (Hydraulic Delay) 7.5A 250 V 80 V Toggle 1 None - -
IUGN11-40844-1-U Sensata-Airpax

IUGN11-40844-1-U

CIR BRKR MAG-HYDR

Sensata-Airpax

2,933
Datasheet IUG Bulk Active Panel Mount Magnetic (Hydraulic Delay) 5A 250 V 80 V Toggle 2 None - -
AA2-B0-24-450-1B7-C Carling Technologies

AA2-B0-24-450-1B7-C

CIRCUIT BREAKER

Carling Technologies

8,771
Datasheet A Bulk Active Panel Mount, Snap-In Magnetic (Hydraulic Delay) 5A 277 V 80 V Lever 2 None - CCC, CSA, UL
AA2-B0-24-610-1B7-C Carling Technologies

AA2-B0-24-610-1B7-C

CIRCUIT BREAKER

Carling Technologies

9,058
Datasheet A Bulk Active Panel Mount, Snap-In Magnetic (Hydraulic Delay) 10A 277 V 80 V Lever 2 None - CCC, CSA, UL
MA016UM Altech Corporation

MA016UM

CIR BRKR THRM 160MA 277VAC LEVER

Altech Corporation

8,979
Datasheet MA Bulk Active DIN Rail Thermal 160mA 480 V - Lever 3 None - CE, cUL, UL508
MA025UM Altech Corporation

MA025UM

CIR BRKR THRM 250MA 277VAC LEVER

Altech Corporation

7,720
Datasheet MA Bulk Active DIN Rail Thermal 250mA 480 V - Lever 3 None - CE, cUL, UL508
MA040UM Altech Corporation

MA040UM

CIR BRKR THRM 400MA 277VAC LEVER

Altech Corporation

9,664
Datasheet MA Bulk Active DIN Rail Thermal 400mA 480 V - Lever 3 None - CE, cUL, UL508
Total 59416 Record«Prev1... 14441445144614471448144914501451...2971Next»
FAQ

Frequently Asked Questions

What are Circuit Breakers components used for?

Circuit Breakers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Circuit Breakers part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Circuit Breakers parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Circuit Breakers?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top